Hoyt Electrical Test Equipment
800-258-3652
 
About Hoyt   Catalogs   Cart    Clients    Reps    Links
 

AC CURRENT M200 Series

AC VOLTAGE M200 Series

Power Relays

Synchronising Check Relay

Phase Sequence Relay

Speed Sensing Relay

DC Transducer Trip Relay

ThermoCouple Trip Relay

Thermister Trip Relay

MilliVolt Trip Relay

DC Voltage Trip Relay

45 Series Control Relays

M1 Series Control Relays

P48 Series Control Relay

M200

70PUCR

70 Series Control Relays

B Series Control Relays

M3 Multifunction Control Relays

45050

45051

45UVR

45OVR

 

 
  Search by Category
 
  
  Search by Product Name
 
  
Products: Relays and Timers > Control Relays > Phase Balance Relay
 
L-Series Switchboard Shunts
Switchboard Shunts
get more info 
SB70116A Current Transformer
Window Size: 7.02" No equivalent ITI Model
get more info 
Round Current Transformers
Round Current Transformer
get more info 
CVMK2
NEW!!! Modular Power Analyzer
get more info 
Model 3125 Analog Panel Meters
Marine Analog Panel Meters
get more info 
 
Phase Balance Relay
 

The M200-PB1 can detect the following conditions in phase 3 or 4 wire systems. Phase Unbalance, Phase Loss, Phase Reversal and Phase Sequence. The phase balance relays are used to detect phase loss and unbalance in systems using motors, generators, heater elements, transformers etc. A Phase unbalance as small as 10% in a 3 phase motor can cause the temperature in the motor winding to increase by more than 120%, correct setting of the PB1/PB2 will ensure this does not occur. Protection against open phase regenerated voltage, created if a single phase should fail is also provided. Customer adjustment of unbalanced voltage between 5 to 15% is provided along with time delay adjustment of 200ms to 10 seconds. If the system being monitored is healthy, the relay is energized, and the red LED will be illuminated. If a phase unbalance greater than the pre-set level or phase loss / reversal occurs, the relay de-energizes after the time delay period. The M200-PB2 provides all the protection features of the PB1 with the additional benefit of having symmetrical under voltage protection. This means that if all the phase voltages remain balanced but drop below a pre-set value, the relay will de-energize. The under voltage is internally set. For standard units it is set at 85% below the nominal voltage, but this value can optionally be between 70% and 90%

   
 
Features & Benefits
 
  • Selection
    M200-PB1 Detects phase loss & phase unbalance
    M200-PB2 Detects phase loss, phase unbalance & symmetrical under-voltage


  • Options
    Adjustable time delay max 30 seconds
    Internal under voltage set between 90% to 70%
    Calibration at nominal Hz 35-450Hz
    Calibration at temperature other than 23° C


 
 