Hoyt Electrical Test Equipment
800-258-3652
 
About Hoyt   Catalogs   Cart    Clients    Reps    Links
 

AC CURRENT M200 Series

AC VOLTAGE M200 Series

Power Relays

Synchronising Check Relay

Phase Sequence Relay

Phase Balance Relay

Speed Sensing Relay

ThermoCouple Trip Relay

Thermister Trip Relay

MilliVolt Trip Relay

DC Voltage Trip Relay

45 Series Control Relays

M1 Series Control Relays

P48 Series Control Relay

M200

70PUCR

70 Series Control Relays

B Series Control Relays

M3 Multifunction Control Relays

45050

45051

45UVR

45OVR

 

 
  Search by Category
 
  
  Search by Product Name
 
  
Products: Relays and Timers > Control Relays > DC Transducer Trip Relay
 
L-Series Switchboard Shunts
Switchboard Shunts
get more info 
Round Current Transformers
Round Current Transformer
get more info 
Hoyt Combo Meter
Now you do not have to choose between analog or digital panel meters
get more info 
CVM-Mini
DIN rail mounted(3 modules) electrical system analyzer
get more info 
800 Series Analog Panel Meters
800 Series Analog Panel Meters
get more info 
 
DC Transducer Trip Relay
 

The M200 DC transducer trips have endless applications. As the name implies they are designed to accept inputs from transducers and transmitters, and provide a relay operation when the transducer signal deviates outside a pre-set limit Any of the M100 series transducers can be used with the transducer trip. A typical application is to control power using a M100-WA5 with a 4-20mA signal fed to a M200- TAO. For example the output goes above a pre-set limit of 80%, the TAO relay will close, setting off an alarm or shutting down a process Either DC voltage or DC current inputs can be used. As is common with all the M200 relays, on over units the relay energizes when the input signal exceeds the trip point and on under units the relay de-energizes when the input signal goes below the trip point A red LED indicates the state of the relay, whilst a green LED indicates the condition of the power supply.

   
 
Features & Benefits
 
  • Selection Guide
    M200-TAU DC volts or mA under trip
    M200-TAO DC volts or mA over trip
    M200-TAC DC volts or mA combined trip


  • Options

    Adjustable time delay max 30 seconds
    AC auxiliary in the range 57.7 to 480 volts
    Calibration at nominal Hz 35-450Hz
    Calibration at temperature other than 23° C



 
 