AT Series Current Transducers

ATP Powered Current Transducers Series

ATQ Series Frequency Output Current Transducers

DT Series DC Current Transducers

LP-IP Auxillary Powered AC Current Transducer

LP-IS Self Powered AC Current Transducer

T-IL Loop Powered AC Current Transducer

T-ILC Loop Powered with integral CT

T-ILE Loop Powered AC Current Transducer

LP-IL Loop Powered AC Current Transducer

LP-ISX3 Three Phase Self Powered AC Current transducer

T-IS Self Powered AC Current Transducer

T-IP AC Current Transducer

M100-DM3 DC Current or Voltage Transducer

M100-DS DC Current Summation Transducer

LP-IRMS SEPARATELY POWERED RMS RESPONDING CURRENT TRANSDUCER

LP-ID AC Current Transducers

ATR Series Current Transducers

AT-ATR 3 and 4 Series Current Transducers

M560 PowerSig

 

 
  Search by Category
 
  
  Search by Product Name
 
  
Products: Transducers > AC and DC Current Transducers > Multitek M100-A Current Transducers
 
M100-DA & DV Isolation Transducers
M100-DA & DV DC Current or Voltage Isolation Transducers
get more info 
M100-R Series Remote Resistance Transducer
Multitek M100-R Series Remote Resistance Transducer
get more info 
LP-1W1H Single Phase Watt Transducer
SINGLE PHASE WATT TRANSDUCER PLUS kW-hour PULSE OUTPUT
get more info 
LP-VD AC Voltage Transducers
Single phase, digital( MODBUS RTU) output voltage transducer
get more info 
APS Series kWh CT
CT measuring kWH on a single and three phase balanced load
get more info 
 
Multitek M100-A Current Transducers
$0.00  
 

The M100 series current transducers are designed to measure AC current in single and 3 phase systems. They convert the AC signal to a DC output that is directly proportional to the input signal. The M100-AA1-AA3 are self powered (i.e. no auxiliary required) average sensing RMS calibrated voltage transducers, mA and voltage outputs are available. The M100-AL1-AA3 are average sensing RMS Calibrated , live zero current transducers. Auxiliary is required to provide power so that 4mA output signal is present, when the input is zero. The M100-AR1 is true RMS sensing RMS calibrated allowing measurement of distorted waveforms of up to the 9th harmonic with a crest factor of 5. The AR1 is typically used in current measurement where distorted waveform is common such as thyristor drives. The above units are used to measure current in energy management systems, switchboards, generator and telemetry controls. Isolation of 4KV is provided between the input and output signal, allowing the output to be fed to conventional analog meters, PLC and computer systems. M100-AA1 1 ph. Self Powered ave. Sensing RMS Calibrated
M100-AL1 1 ph. Aux. Powered Ave. Sensing RMS Calibrated
M100-AR1 1 ph. Aux. Powered True RMS Sensing RMS Calibrated
M100-AA3 3 ph. Self Powered Ave. Sensing RMS Calibrated
M100-AL3 3 ph. Aux. Powered Sensing RMS Calibrated

   
 
Features & Benefits
 
  • Options
    1. Non standard inputs / outputs only as far as technically acceptable.
    2. AC auxiliary in ranges 57.7 to 450 Volts.
    3. Calibration at nominal Hz 35-450Hz
    4. Calibration at temperature other than 23°.


 
 