189 DM autoranging digital multimeter
AC Voltage
Ranges: 400mV / 4V / 40V / 400V / 750V
Resolution: 0.1mV / 1mV / 10mV / 100mV / 1V
Accuracy: ±(1.0%rdg+5dgt)
Input impedance : 10MΩ
DC Voltage
Ranges: 400mV / 4V / 40V / 400V / 1000V
Resolution: 0.1mV / 1mV / 10mV / 100mV / 1V
Accuracy: ±(0.5%rdg+3dgt)
Input impedance : 10MΩ
AC mA / µA
Ranges: 400µA / 4000µA / 40mA / 400mA
Resolution: 0.1μA / 1μA / 0.01mA / 0.1mA
Accuracy: ±(1.0%rdg+6dgt)
Overload Protection 0.5A/250V fast blow fuse for 400mA
DC mA / µA
Ranges: 400µA / 4000µA / 40mA / 400mA
Resolution: 0.1μA / 1μA / 0.01mA / 0.1mA
Accuracy: ±(1.0%rdg+6dgt)
Overload Protection 0.5A/250V fast blow fuse for 400mA
Frequency
Ranges: 4 kHz / 40 kHz / 100 kHz
Resolution: 1Hz / 10 Hz / 100 Hz
Accuracy: ±(0.5%rdg+2dgt)
Continuity
Ranges: 400.0Ω
Audible threshold: Less than 25Ω
Diode
Ranges: 2V
Accuracy: ±(1.5%rdg+3dgt)
GENERAL
Dimensions: 165mm(L) x 82mm(W) x 45mm(D)
Weight (battery included): Approx. 246g
Power source: 1.5V (AAA) battery x 2
Safety standard: EN 61010-1 CAT III 600V, EN 61010-2-30, EN 61326-1
888 PMR phase rotation and motor rotation tester
Measurement principle: contact Live Wire.
Input voltage: 100-600V AC.
Frequency range: 40-400Hz.
Operating temperature & humidity: 0°C ~ 40°C Max. 80% R.H.
Storage temperature & humidity: -10°C ~ 50°C Max. 80% R.H.
Cable length: Approx. 60cm
Dimensions: 128(L) x 72(W) x 44(D)mm
Weight (battery included): Approx. 220g
Power source: 9V (6F22) × 1
Safety standard: EN 61010-1 CAT III 600V, EN 61326-1EN 61557-1, EN 61557-7.
LVD-15 non-contact voltage detector.
Voltage detection: 50V~1000V AC
Frequency: 50~500 Hz
Measurement category: CAT III 600V
Indication: LED and Tone
Operating conditions: Temperature: 0~40°C | Humidity: Less than 80% R.H. | Altitude: 2000m maximum
For indoor use only
Pollution degree: 2
Dimensions: 142(L) × 28(W) × 27(D)mm
Weight (battery included): Approx. 45g
Power source: 1.5V (AAA) × 2
Safety standard: EN 61010-1 CAT III 600V, EN 61326-1.