Microprocessor-controlled.
Automatic voltmeter AC/DC at Start/Reset.
Auto range.
Auto off.
Battery test.
Battery test at switch ON/Reset.
Safety voltmeter before each test.
Auto discharge on all test and all ranges.
Leads Auto-Null key.
Test Auto-Stop.
Smart hold & stop on voltmeter ac/dc.
Ener-Save feature to extend battery life.
Continuity short circuit current > 220mA.
Continuity open circuit voltage of 5Vdc.
Nominal voltage @ 1mA on all insulation ranges.
Accept 8 rechargeable batteries or Alkaline of normal.
BS 16 edition.
Accessories
Instruction manual,
Test leads,
Shoulder belt,
Soft pouch,
Batteries.
Insulation Resistance
Test voltage: 50V / 100V / 125V / 250V / 500V / 1000V
Measuring ranges: 0.1MΩ ~ 400MΩ / 0.1MΩ ~ 800MΩ / 0.1MΩ ~ 1GΩ / 0.2M~2GΩ / 0.2M~4GΩ / 0.2M~8GΩ
Accuracy:
0.1MΩ~4GΩ: ±3%rdg
4GΩ~8GΩ: ±5%rdg
Metal Oxyde Varistor (MOVs) & Gas Arrester (GAS) Voltage Result @ 1mA
Test Voltage: 5 ~ 1020V
Accuracy: ±3%rdg±2dgt
PI=Polarization Index
DAR=Dielectric Absorption Ratio
Continuity
Range: 0.01 ~ 100Ω / 100 ~ 300Ω / 300 ~ 1999Ω
Accuracy: ±1%rdg / ±1.5%rdg / ±2%rdg
Auto-Null Up to 5Ω
Buzzer Threshold Value Up to 3Ω
Voltmeter
Range: 0 ~ 700Vac / 0 ~ 950Vdc
Accuracy: ±1.5% F.S. / ±1.5% F.S.
Resolution: ±1V
Auto-Hold
Battery load current: Approx. 300mA
L.C.D type: Large Type 2 × 16 Characters
Auto-off: Approx. 5 minutes
Fuse: Fast HBC 500mA 600V (5 × 20mm)
General
Operating temperature: 0°C to 40°C not in full sun
Storage temperature: -10°C to 50°C
Dimensions: 175(L) × 85(W) × 75(D)mm
Weight (battery included): Approx. 655g
Power source: 1.5V (AA) × 8 Alkaline batteries
Auto discharge on all test and all range
Safety Standard
EN 61010-1 CAT III 600V
EN 61326-1