Insulation Resistance
Test voltage (DC V) |
Measuring ranges (Auto ranging) |
Resolution |
Accuracy |
|
50V 100V 125V 250V |
50kΩ~400MΩ 100kΩ~800MΩ 125kΩ~1GΩ 250kΩ~2GΩ |
1kΩ~1MΩ 1kΩ~1MΩ 1kΩ~1MΩ 1kΩ~10MΩ |
50kΩ~4GΩ: ±3%rdg |
|
500V 1000V |
500kΩ~4GΩ 1MΩ~8GΩ |
1kΩ~10MΩ 10kΩ~10MΩ |
50kΩ~4GΩ: ±3%rdg |
|
Output voltage open circuit: +10%
Output current: Up to 1mA DC
AC Voltage
Range: 0~600V
Resolution: 1V
Line frequency range: 50Hz / 60Hz
Accuracy: ±1.5%rdg
DC Voltage
Range: 0~ ±600V
Resolution: ±1V
Accuracy: ±1.5%rdg
Continuity
Ranges: 100Ω / 200Ω
Resolution: 0.01Ω / 0.1Ω
Short circuit terminal current: ≤ 100mA DC min.
Open circuit terminal voltage ≥ 2.5V DC min.
Accuracy: ±1.5%rdg
MOV Test
Test Voltage: 90 ~ 1080Vdc
Voltage Results Accuracy: ±3%
General
Dimensions: 175(L) x 85(W) x 75(D)mm
Weight (battery included): Approx. 665g
Power source: 1.5V alkaline (AA) x 8 batteries.
Accessories
Instruction manual
Test leads
Soft pouch
Shoulder belt
Batteries
Safety Standard
IEC/EN 61010-1 CAT III 600V
EN 61326-1