Overload: 50% momentary; 20% sustained.
Accuracy: ±2% full scale value.
Resistance: ±15%.
Movement: AC Current Movement.
Dials: 100 or 90 degree arc, black lettering on white background.
Pointer: Knife Edge.
Case: Clear polystyrene cases standard. Acrylic or high impact polycarbonate case are available in some models.
Mounting: Specify (S) Surface mount or (B) Bezel mount.
General
Operating Temperature: 32°F to 104°F (0°C to 40°C).
Storage Temperature: -4°F to 131°F (-20°C to 55°C).
Relative Humidity: 20% to 80%RH (Nominal Use).
Meter Approvals: ANSI C39.1, RoHS, REACH.
Origin: Made in USA.
Part Number |
Range |
Scale |
Term Resistance |
|
2046/10VAC
2046/15VAC
2046/25VAC
2046/30VAC
2046/50VAC
2046/100VAC
2046/150VAC
2046/300VAC
2046/500VAC
2046/600VAC
|
FS = 10VAC
FS = 15VAC
FS = 25VAC
FS = 30VAC
FS = 50VAC
FS = 100VAC
FS = 150VAC
FS = 300VAC
FS = 500VAC
FS = 600VAC
|
0-10VAC
0-15VAC
0-25VAC
0-30VAC
0-50VAC
0-100VAC
0-150VAC
0-300VAC
0-500VAC
0-600VAC
|
360
75
1315
1630
9100
16100
26100
51100
83600
96100
|
|
2046R/15VAC (Rectified)
2046R/25VAC (Rectified)
2046R/30VAC (Rectified)
2046R/50VAC (Rectified)
2046R/100VAC (Rectified)
2046R/150VAC (Rectified)
2046R/300VAC (Rectified)
|
FS = 15VAC
FS = 25VAC
FS = 30VAC
FS = 50VAC
FS = 100VAC
FS = 150VAC
FS = 300VAC
|
0-15VAC
0-25VAC
0-30VAC
0-50VAC
0-100VAC
0-150VAC
0-300VAC
|
|
|
Other Ranges available upon request. Custom dials, input and illumination available.