2660 CL AC/DC Clamp Meter

SKU:
2660CL
$333.00

AC/DC Digital Clamp Meter for Voltage, Current, Resistor, Diode, Capacitor measurement and Frequency counter.

  • Safety design throughout with no exposed metal parts, shielded banana plugs and recessed input terminals.
  • Operating principle: Dual slope integration.
  • 4000 counts LCD with Bar graph indication.
  • Function: Range change. Data hold. REL. Peak function. Max / Min. Auto Power Off (APO).
  • Indication: Low battery. Over range.
$333.00

Specifications

● DC Voltage: 400mV. 4V. 40V. 400V. 600V.
- Resolution: 0.1mV. 1mV. 10mV. 100mV. 1V.
- Accuracy: ±(1.0%rdg+3dgt).
● AC Voltage: 400mV. 4V. 40V. 400V. 600V.
- Resolution: 0.1mV. 1mV. 10mV. 100mV. 1V.
- Accuracy: ±(0.5%rdg+3dgt) for 400mV. ±(1.5%rdg+3dgt) for 4V-600V.
● DC / AC Current
- Range 400A. Resolution: 0.1A. Accuracy: ±(1.5%rdg+4dgt).
- Range 600A. Resolution: 1A. Accuracy: ±(2.0%rdg+4dgt).
● Resistance: 400Ω. 4kΩ. 40kΩ. 400kΩ. 4MΩ. 40MΩ.
- Resolution: 0.1Ω. 1Ω. 10Ω. 100Ω. 1kΩ. 10kΩ.
- Accuracy: ±(1.5%rdg+3dgt). ±(2.0%rdg+4dgt) for 40MΩ.
● Capacitance: 4nF. 40nF. 400nF. 4µF. 40µF. 400µF. 4mF. 40mF.
- Resolution: 1pF. 10pF. 100pF. 1nF. 10nF. 100nF. 1µF. 10µF.
- Accuracy: ±(2.5%rdg+4dgt) for 4nF. ±(2.0%rdg+4dgt) for 40nF-40µF. ±(2.5%rdg+4dgt) for 400µF-4mF. ±(3.0%rdg+4dgt) nfor 40mF.
● Frequency: 4kHz. 15kHz.
- Resolution: 1Hz. 10Hz.
- Accuracy: ±(0.3%rdg+2dgt).
● Continuity: 400Ω.
- Audible threshold: < 35Ω.
● Diode: 2V.
- Resolution: 1mV.
- Accuracy: ±(1.5%rdg+3dgt).
● Conductor size 35mm Max.
● Response time: Approx. 1 second.
● Sample rate: Approx. 2 times per second.
● Operating / Storage Temp. & humidity: 0ºC~50ºC / -10ºC~60ºC, 80% Max.
● Battery life: Approx. 100 hours on continuous use. (Alkaline).
● Dimensions: 210(L) × 90(W) × 40(D)mm.
● Weight (battery Included): Approx. 330g.
● Power source: One type 6F22 (or equivalent), 9V manganese.
● Safety Standard: EN 61010-1 CAT III 600V. EN 61326-1.