The Model 3410 LCD Hour Meter provides a large display with 0.28” [7mm] high characters, available in 5 different industry size housings.
A wide operating voltage, 10-300VDC and 20-300VAC, makes the model 34 versatile for all indoor and outdoor applications. All models are NEMA 4/4X, 12 & IP66 rated when used with the optional gasket and have a polarized lens which assures high visibility in an outdoor environment.
Features
Totally sealed from moisture and dirt.
AC or DC voltage input in the same unit.
Compact depth.
Fits in existing panel openings.
Always on display.
Options:
- A choice of 5 housings.
- Optional Remote Reset.
Applications:
Medical Devices..
Generators.
Control Panel.
Production Equipment.
Garden.
Tractor.
Marine Equipment.
Display: LCD with large 0.28” [7mm] high figures black on light background.
Run Indicator: Blinking decimal point.
Reset: Remote and non-reset.
Resolution: 0.1 Hour displayed.
Accuracy: ± 0.1% @ room temperature ± 0.2% over the specified temperature range.
Records & Displays: 9999999.9 (hours and 1/10ths).
Inputs:
10-300VDC and 20-300VAC - 50/60Hz <2mA.
VIH 20VAC or 10VDC minimum.
VIL 3VAC or 3VDC maximum.
Power: Self-powered - battery life 10+ years.
Terminations: Standard 0.250” [6.4mm] spades.
Enclosure: Totally sealed from moisture and dirt. NEMA 4/4X, 12 & IP66 compliant from the front when properly mounted using the optional gasket. (Not applicable in the Snap-In Model).
General
Operating Temp.: -10˚C to +60˚C [14˚F to +140˚F].
Storage Temp.: -20˚C to +70˚C [-4˚F to +158˚F].
Humidity: 95% RH per SAE J1378.
Vibration: 20g @ 10 to 80 Hz per SAE J1378. Shock: 44 to 55g’s per SAE J1378.
Dielectric: 1000VAC 50/60 Hz for 1 minute (34x0 models only).
Compliance: Compliant to the European WEEE and RoHS Directives.
Sealing: Totally sealed.
EMC Compliance: EN61326.
Protection Against: Alternator load dump: 150V EMI (Electromagnetic Interface): +400V @ 500Hz inductive switching and reverse polarity.
Weight: 1 oz. [28g].
Approvals: UL & cUL recognized (file # ELIY2.E36690), CE, SAE, NEMA 4/4X/IP66 compliant (not including 3410-2210).
Ordering Information
H3410-0000 AC/DC Hour Meter 2-hole case 1/4” non-reset. Gasket H5003-010.
H3410-0010 AC/DC Hour Meter 2-hole case 1/4” remote-reset. Gasket H5003-010.
H3410-1000 AC/DC Hour Meter 3-hole case 1/4” spade terminals non-reset. Gasket H5003-017.
H3410-1010 AC/DC Hour Meter 3-hole case 1/4” spade terminals remote-reset. Gasket H5003-017.
H3410-2000 AC/DC Hour Meter flush rectangular case 1/4” spade terminals non-reset. Gasket H5003-009.
H3410-2010 AC/DC Hour Meter flush rectangular case 1/4” spade terminals remote-reset. Gasket H5003-009.
H3410-3000 AC/DC Hour Meter round SAE case 1/4” spade terminals non-reset. Gasket H5003-009.
H3410-3010 AC/DC Hour Meter round SAE case 1/4” spade terminals remote-reset **special order** MOQ=50pc. Gasket H5003-009.
H3410-5000 AC/DC Hour Meter snap-in case 1/4” spade terminals non-reset.
H3410-5010 AC/DC Hour Meter snap-in case 1/4” spade terminals remote reset.
5003-010 NEMA 4X Gasket two hole mount
5003-017 NEMA 4X Gasket three hole mount
5003-009 NEMA 4X Gasket flush rectangular and SAE round mount