ACV / DCV |
Range 400mV 4V 40V 400V 600V |
Resolution 0.1mV 1mV 10mV 100mV 1V |
ACV Accuracy (at 40-500Hz) ± (2.0% rdg+3dgt) ± (1.5% rdg+3dgt) ± (1.5% rdg+3dgt) ± (1.5% rdg+3dgt) ± (1.5% rdg+3dgt) |
DCV Accuracy ± (1.0% rdg+3dgt) ± (1.0% rdg+3dgt) ± (1.0% rdg+3dgt) ± (1.0% rdg+3dgt) ± (1.0% rdg+3dgt) |
|
ACA / DCA |
Range 400A 1200A |
Resolution 0.1A 1A |
Accuracy ± (1.5% rdg+4dgt) ± (2.5% rdg+4dgt |
|
|
Resistance |
Range 400Ω 4KΩ 40KΩ 400KΩ 4MΩ 40MΩ |
Resolution 0.1Ω 1Ω 10Ω 100Ω 1KΩ 10KΩ |
Accuracy
± (1.5% rdg+3dgt)
|
|
|
Diode Test |
Range: 2V |
Resolution: 1mV |
Accuracy: ± (1.5% rdg+3dgt) |
|
|
Continutity Test |
Range: 400Ω |
Audible threshold: Less than 35Ω |
|
|
|
NCV Test |
Range: 50V~1000V AC |
Frequency: 50Hz~500Hz |
|
|
|
General
Measurement category: CAT III 600V
Indication: LED and Tone
Temperature: 0~40°C
Operating conditions:
Humidity less than 80% R.H. For indoor use only
Buzzer: < 35Ω
Conductor size: 40mm max.
Low battery indication:
Dimmensions: 255(L) x 80(W) x 35(D) mm
Weight: Approx. 420g (battery included)
Power Source: 9V (6F22) × 1
Safety standard: EN 61010-1 CAT III 600V, EN 61010-2-32, EN 61010-2-33, EN 61326-1.
Accessories:
- Instruction manual
- Test leads
- Soft pouch
- Battery