THE FIRST ANALOG/DIGITAL METER - THE HOYT COMBO SERIES
Hoyt has resolved forever the question of choosing between digital or analog panel meters with the new Combo Series. For the first time, all of the advantages of both analog and digital panel meters are combined in one meter. The Combo Series features the same precision analog meter movement you expect from Hoyt, with the addition of a 3 ½ digit, bright red, digital display featuring 0.37" high digits. For all their innovation, the new Combo Series meters are completely compatible with existing analog-only or digital panel meter- applications.
SIGNAL- AND LOOP-POWERED
With the addition of what amounts to a digital panel meter (DPM) in an analog panel meter case, questions immediately arise regarding input signal and power supply common, ground, “floating”-, single ended, or differential inputs. Hoyt resolves these questions too, very simply — the new Combo Series meters are self-powered, 2-wire meters. That means there are only two connections, the + and – leads of the input signal. The entire meter, both analog and digital displays, is fully powered by the signal being measured. There are never any grounding or signal- reference questions.
SIGNIFICANT SPACE SAVINGS
Regardless of whether you use analog or digital panels meters now, incorporating Hoyt’s Combo Series will provide a significant space savings in your next application. If you are using analog panel meters now, you can instantly achieve the added benefit of both by upgrading to a Hoyt Combo Series meter. It’s fast, easy, and the two-wire connections allow the Combo Series to upgrade virtually any analog meter application.
MODELS FOR YOUR APPLICATION
Large, bright red LED digital displays are available in Combo Series meters to monitor a wide variety of AC voltage, DC voltage, and frequency ranges. Hour meters are available in the Combo Series with LCD digital displays. With the most popular signals and ranges addressed, Hoyt has a Combo Series meter to meet your specifications.
ANALOG METER Specifications
Accuracy: ±2% of full scale.
Overload: 20% sustained.
Ranges: AC and DC; many options available.
DIGITAL METER Specifications
General
Digital Display: 0.37"/9.4mm digits; bright red LED.
Sampling Rate: 2.5 readings/second.
Accuracy: At 25°C unless noted otherwise.
Measurement Type: AC: Half-wave average, rms; calibrated for sinusoidal input | DC: Standard “+”; Ground “–“.
Temperature Drift: AC Volts: ±0.15V/°C maximum; -25°C to +60°C | DC Volts: ±0.3 counts/°C maximum.
Current Consumption: 50mA maximum; range dependen.
Operating Temp.: -25°C to +60°C.
Storage Temp.: -40°C to +75°C.
Humidity: 0 to 95% (Non-condensing).
Hour Meter
Input Voltage Range: 4.5 to 19VDC; 9 to 60VDC | 36 to 185VDC; 75 to 270VAC.
Resolution: 0.1 Hour.
Accuracy: ±0.1% Hours, ±1 count.
Non-Volatile Memory: -40°C to +89°C; SAE.
Display: 5mm; 6 digits (99,999.9 Hours).
DC Voltage
Input Voltage Range: 2 to 6VDC; 4.5 to 19.99VDC | 18 to 50VDC; 30 to 264VDC.
Resolution: 0.5% to 3.3%, range dependent*.
Accuracy: ±0.5% to ±3.3%, range dependent*.
*Refer to DC Voltage Ranges table.
DC Amperes
Source Voltage: 5VDC minimum.
Input Voltage Range: 0 to 50mVDC; 0 to 100mVDC.
Resolution: 1 count.
Accuracy: ±1%.
Shunts: External; 50 or 100mVDC compatible; Field adjustable.
Scaling: Application-cpecific
4-20MA Current Loop
Input Range: 4mADC minimum; 20mADC maximum.
Voltage Drop: 5VDC.
Accuracy: ±0.05%, ±1 count.
Resolution: 0.01mA minimum; scale dependent.
Zero: Field adjustable.
Gain: Field adjustable.
Scale: Between 0 to 1999; DIP selectable.
ANALOG METER OPTIONS
Part Number |
Range |
Scale |
Term Resistance (self shielded) |
Term Resistance (ext magnet) |
|
5035-Combo/20UADC
5035-Combo/50UADC
5035-Combo/100UADC
5035-Combo/200UADC
5035-Combo/500UADC
5035-Combo/25-0-25UADC
5035-Combo/50-0-50UADC
5035-Combo/100-0-100UADC
5035-Combo/500-0-500UADC
|
FS = 20UADC
FS = 50UADC
FS = 100UADC
FS = 200UADC
FS = 500UADC
FS = 25-0-25UADC
FS = 50-0-50UADC
FS = 100-0-100UADC
FS = 500-0-500UADC
|
0-20UADC
0-50UADC
0-100UADC
0-200UADC
0-500UADC
25-0-25UADC
50-0-50UADC
100-0-100UADC
500-0-500UADC
|
N/A
3900
2600
1000
230
3900
2600
1000
50
|
3500
2200
2200
900
200
2200
2200
900
60
|
|
5035-Combo/1MADC
5035-Combo/5MADC
5035-Combo/10MADC
5035-Combo/25MADC
5035-Combo/50MADC
5035-Combo/100MADC
5035-Combo/150MADC
5035-Combo/200MADC
5035-Combo/300MADC
5035-Combo/500MADC
|
FS = 1MADC
FS = 5MADC
FS = 10MADC
FS = 25MADC
FS = 50MADC
FS = 100MADC
FS = 150MADC
FS = 200MADC
FS = 300MADC
FS = 500MADC
|
0-1MADC
0-5MADC
0-10MADC
0-25MADC
0-50MADC
0-100MADC
0-150MADC
0-200MADC
0-300MADC
0-500MADC
|
50
8
3
0.66
0.55
0.27
0.16
0.14
0.14
0.6
|
50
8
3
0.66
0.55
0.27
0.16
0.14
0.14
0.6
|
|
5035-Combo/1ADC
5035-Combo/3ADC
5035-Combo/5ADC
5035-Combo/10ADC
5035-Combo/15ADC
5035-Combo/25ADC
5035-Combo/30ADC
5035-Combo/50ADC
|
FS = 1ADC
FS = 3ADC
FS = 5ADC
FS = 10ADC
FS = 15ADC
FS = 25ADC
FS = 30ADC
FS = 50ADC
|
0-1ADC
0-3ADC
0-5ADC
0-10ADC
0-15ADC
0-25ADC
0-30ADC
0-50ADC
|
0.0500
0.0166
0.0100
0.0050
0.0033
0.0020
0.0017
0.0010
|
|
|
DIGITAL METER OPTIONS
DC Voltmeter |
Part Number |
Range |
Resolution |
Accuracy |
|
/26VD /520VD /1850VD /30264VD |
+2.00 to +6.00 +4.50 to +19.99 +18.0 to +50.0 +30 to +264 |
0.01 0.01 0.1 1 |
+/-0.01 +/-0.01 +/-0.1 +/-1 |
DC Millivoltmeter
|
Part Number |
Range |
Analog Scale |
|
|
/50MVDC /100MVDC |
0 to 50MVDC 0 to 100MVDC |
Specify Scaling Specify Scaling |
|
DC Ammeter, 4-20MADC LOOP
|
Part Number |
|
Analog Scale |
|
|
/42LP102 |
|
Specify Scaling |
|
|
Other Ranges available upon request. Custom dials, input and illumination available.