Electrical
Resistance Ranges:
- The L-E led will lit when the resistance between Line to Earth is lower than 1MΩ ±5%
- The N-E led will lit when the resistance between Neutral to Earth is lower than1MΩ±5%
- The EARTH BOND led will lit when the resistance between the EARTH to the Probe is higher than 10Ω±5%
Test Current:
- Line to Earth test current is 9uA maximum
- Neutral to Earth test current is 9uA maximum
- Earth to Probe test current is 2.3mA maximum
Maximum Output Voltage: 9V rm
Response Time: 0.1secs nominal
Voltage Withstand: 6V AC between any two terminals
Battery Low Indication point: 7V nominal
General
Operating temperature: -15 ºC to + 55 ºC
Storage Temperature: -20 ºC to + 70 ºc
Size: 72mm x 150mm x 36 mm
Material: ABS
Weight (less carrying case): Approx.194g (with battery)
Display: LEDs
Battery: 9V(6F22) x 1
Safety standard: EN 61326-1