Decimal Points: 3 position, user-selectable
Overrange: three lower order digits blank for inputs >1999
Configuration: bipolar differential
Protection: ±350VDC (±100VDC on 200MVDC range)
Impedance: 300Ω nominal
Accuracy: (±0.1% FS + 1 count) typical
Sample Rate: 3 readings per second
Normal Mode Rejection: >30DB @60HZ
Common Mode Range: ±1VDC
Common Mode Rej.: >86DB
Adjustments: span and zero
Warmup: 10 minutes typical
Temperature Coeff.: ±100PPM per °C
Operating Temperature: 0 to 50°C
Storage Temperature: -20 to 75°C
Optional Backlight: 24VDC at 35MADC typical
Connection: 2 screw terminals
For complete specifications consult the datasheet.
RETURNS, CREDIT & EXCHANGES
Hoyt Electrical Instrument Works Inc. (Hoyt) warranties its products to be free of defective materials and workmanship for a period of (1) year after shipment to the original purchaser. This warranty shall be limited to defective materials and workmanship; it will not cover those products, which have been damaged due to improper handling, storage, installation or operation by the purchaser or any third party.
At Hoyt’s discretion defective products may be repaired or replaced and the products returned to proper working condition. All warranty claims must be made by calling the factory directly at 1-800-258-3652. Return shipments must be made in the original packaging or packaging of equal quality that will provide appropriate protection during shipping.
Hoyt will not be responsible for the warranty repair of products returned via inadequate containers and packaging, nor for missing components. Hoyt shall not be liable for any special, punitive, incidental or consequential damages made by the buyer or any third party. This statement of warranty is in lieu of all other warranties, guarantees, liabilities and obligations, statutory or implied to the original purchaser or to any other party.