  • Theta 10A/10V AC to DC Transducer

    Theta 10A/10V AC to DC Transducer

    The DIN Rail mount Theta 10A/10V is used to measure and convert an AC Voltage or Current input signal to a load independent DC Voltage or Current signal. Choose the option which best works for your application. Voltage Input: 63.5V to 500V; Current Input: 1A to 5A; Frequency: 50 or 60Hz; DC Output: ...
  • Theta 20A/20V AC to DC Transducer

    Theta 20A/20V AC to DC Transducer

    Voltage Input: 57V to 500V; PT Primary Range: 57V to 400kV; Current Input: 1A to 5A; CT Primary Range: 1A to 9999A; Power Supply: 60 to 300VAC/VDC or 24 to 60VAC/VDC; Output: 0-20mA, 4-20mA, or 0-10V (DIP Switch Selectable); Programming: RS-232 with optional cable; Used to measure and convert an AC ...
  • Theta 30P Power Quality Transducer

    Theta 30P Power Quality Transducer

    The Theta 30P measures and converts active, reactive, apparent power, phase angle and power factor in both single phase and three phase AC systems. Nominal Input Voltage: 100V to 500V Line to Line; PT Primary Range: 100V to 692KV Line to Line; Frequency: 25Hz to 60Hz; Nominal Input Current: 1A to 5A...
  • Theta 40 Multi-variable AC to DC Transducer

    Theta 40 Multi-variable AC to DC Transducer

    Input Voltage: Up to 693V (Phase to Phase); Power Supply: 24-80VAC/VDC or 85-230VAC/VDC; Mounting: 35MM DIN; Measures several variables of an electric power system such as current, voltage (rms), power factor, apparent power, and reactive power; Converts signal to DC analog or digital signals depend...
  • Theta 50 Isolation Transducer

    Theta 50 Isolation Transducer

    DC Current Range: 0-20mA or 4-20mA; DC Voltage Range: 0-10V; Power Supply: 60 to 300VDC/VAC; Operating Temperature: -10°C to 55°C / -14°F to 131°F; Measures the suspect DC signal and provides isolation through two available analog outputs; Isolator addresses the concerns of electroma...
  • Theta 60M Universal Transmitter

    Theta 60M Universal Transmitter

    DC Voltage: -300 to 300mV, -40 to 40V; DC Current: -12 to 12mA, -50 to 100mA; Resistance: 0 to 740Ω, 0 to 5000 Ω; Thermocouple (TC): -300 to 300mV; Power Supply: 24 to 60VDC/VAC or 85 to 230VDC/VAC; Converts a DC current, voltage, or a signal for a thermocouple, resistance thermometer, r...
  • Theta 60R RTD Temperature Transducer (PT100)

    Theta 60R RTD Temperature Transducer (PT100)

    Input: PT100 RTD (2,3, or 4 Wire); Power Supply: 24-60VAC/VDC or 85-230VAC/VDC; Outputs: 0-20mA/4-20mA or 0-10V; DIN rail mount converts the resistance value from a PT100 RTD into an analog signal for display, recording, or monitoring; Range and calibration handled through a series of DIP switches a...
  • Theta Hz Frequency Transducer

    Theta Hz Frequency Transducer

    Input: 100-500VAC; Input Frequency: 50 or 60Hz; Power Supply: 60-300VAC/VDC or 24-60VAC/VDC; Operating Temperature: 0°C to 45°C / 32°F to 113°F; Takes the measured frequency sine or distorted wave and converts it to a linear analog output; Output signal can be set to a voltage or cur...